| Typical Characteristics
Test Conditions: 25º C ambient This series of low profile 45-55 Watt AC to DC switchers come in 12 different models. These units offer high efficiency and precise regulation throughout the operating temperature range of -25º C to +70º C ambient, with no heat sink or electrical heating required. The 50AC Series keeps a maximum of 0.500" height while still offering you 1200 volts RMS isolation in a rugged encapsulated case. The convenience of PC mounting and the availability of three outputs should aid your circuit design. |
Features
|
|
Series
50AC Single Output
|
Series 50AC
Dual Output
|
Series 50AC Single Output |
|||||||||
| Pico Part No. |
Output Voltage (VDC) |
Max. Load Current (mA) |
Max. Output Power (watts) |
EFF
@ Full Load Typical (%)* |
Output Voltage Ripple @ Full Ld. 1-1 MHz BW mv p-p |
Output Voltage Tolerance (± %)* |
V
LD. Reg. 10%-100% Load** (± %)* |
Line Regulation (± %)* |
Price |
|---|---|---|---|---|---|---|---|---|---|
|
50AC5S
|
5
|
9000
|
45
|
75
|
50
|
1.0
|
0.75
|
0.2
|
384.13
|
|
50AC12S
|
12
|
4583
|
55
|
80
|
50
|
0.5
|
0.30
|
0.2
|
384.13
|
|
50AC15S
|
15
|
3667
|
55
|
83
|
50
|
0.5
|
0.30
|
0.2
|
384.13
|
|
50AC24S
|
24
|
2292
|
55
|
86
|
50
|
0.5
|
0.30
|
0.2
|
384.13
|
|
50AC28S
|
28
|
1964
|
55
|
86
|
50
|
0.5
|
0.30
|
0.2
|
384.13
|
| *Readings Taken at 115VAC-60Hz. at full load **10% minimum load required *** All units available with 170-240VAC input. Add H prefix to part number - $40 per unit cost added. |
|||||||||
Series 50AC Dual OutputInput Voltage 90-130VAC (47-440Hz)(Optional 170-240VAC, 47-440 Hz)*** |
|||||||||
| Pico Part No. |
Output Voltage (VDC) |
Max. Load Current (mA) per output |
Max. Output Power (watts) per output |
EFF @ Full Load Typical (%)* |
Output Voltage Ripple @ Full Ld. 1-1 MHz BW mv p-p |
Output Voltage Tolerance (± %)* at full load each output |
V LD. Reg. 10%-100% Load** (± %)* |
Line Regulation (± %)* at full load each output |
Price |
|---|---|---|---|---|---|---|---|---|---|
|
50AC5D
|
±
5
|
4500
|
22.5
|
75
|
50
|
1.0
|
0.75
|
0.2
|
403.39
|
|
50AC12D
|
±
12
|
2291
|
27.5
|
80
|
50
|
0.5
|
0.3
|
0.2
|
403.39
|
|
50AC15D
|
±
15
|
1833
|
27.5
|
83
|
50
|
0.5
|
0.3
|
0.2
|
403.39
|
| *Readings Taken at 115VAC-60Hz. **10% minimum load required *** All units available with 170-240VAC input. Add H prefix to part number - $40 per unit cost added. |
|||||||||
Options Available per MIL-STD-883:
|
Series
50AC Triple Output
|
Series 50AC Triple Output |
||||||||||||
| Main Output Voltage | Auxiliary Output Voltage | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pico Part No. |
Output Voltage (VDC) |
Max. Load Current (mA) Output |
Max. Output Power (watts) Output |
V LD. Reg. 25%- 100% Load (± %)* |
Output Voltage Ripple @ Full Ld. 1-1 MHz BW mv p-p |
Output Voltage (DC) Per Output |
Max. Load Current (mA) Per Output |
Max. Output Power (watts) Per Output |
Volt. Load Reg. 25%- 100% Load** (± %)* |
Output Ripple @ Full Ld. 1-1 MHz BW mv p-p* |
EFF @ Full Load Typical (%) |
Price |
|
50AC5T12
|
5
|
8000
|
40
|
0.75
|
50
|
±
12
|
208
|
2.5
|
1.0
|
50
|
75
|
422.65
|
|
50AC5T15
|
5
|
8000
|
40
|
0.75
|
50
|
±
15
|
167
|
2.5
|
1.0
|
50
|
75
|
422.65
|
|
50AC12T5
|
12
|
3750
|
45
|
0.25
|
50
|
±
5
|
500
|
2.5
|
1.0
|
50
|
77
|
422.65
|
|
50AC15T5
|
15
|
3000
|
45
|
0.25
|
50
|
±
5
|
500
|
2.5
|
1.0
|
50
|
79
|
422.65
|
|
|
Common Characteristics Main Output Voltage Tolerance ± 0.5% Main Line Regulation ± 0.2% |
Common
Characteristics Auxiliary Output Voltage Tolerance ± 5% Auxillary Line Regulation ± 0.2% |
|
|||||||||
| *Measurements Taken at 115VAC-60Hz. **10% minimum load required ***All units available with 170-240VAC input. Add H prefix to part number - $40 per unit cost added. |
||||||||||||