Military DC-DC Converters

Series FC/MC Single and Series FC/MC Dual

Isolated Regulated 100 Watts, Wide Input Range/100-180 VDC
Fully Regulated, Short Circuit Protected
Parallel Operation Available

Features:
  • Dual isolated outputs
  • Short circuit protection
  • Input voltage protection
  • Thermal, over temp. shutdown
  • Line regulation
  • Load regulation
  • No external components required
  • Hi density, hi efficiency design
  • Remote shutdown
  • Trim capabilities
  • Fixed frequency-100 Khtz
Typical Characteristics: 

Frequency: 100 Khtz
Base plate: Max. +85º C
Operating temperature: See thermal chart: -40º C to +85º C base plate, -55º C to +85º C base plate.
Test conditions: 25º C ambient
Isolation Base Input: 2121 VDC
Isolation Input Output: 4242 VDC
Isolation Output to Base: 1000 VDC
Storage temperature: -55º C to +105º C

    50 Standard Models
For all variations, call factory. 

For Parallel Operation: Add suffix "P" (i.e. FC/MC5SP).
Consult factory to optimize for your application.

Series FC : (-40º C to +85º C Operating Temperature)
Series MC : (-55º C to +85º C Operating Temperature)
Surge Meets MIL STD 704
Vibration Meets MIL STD 202 Method 204 Cond. D
Humidity Meets MIL STD 202 Method 106
Shock Meets MIL STD 202 Method 213 Cond. I
Altitude Meets MIL STD 202 Method 105 Cond. D
Selected MIL STD 883 Options also Available
Stabilization Bake MIL STD 883 Method 1008 24 Hrs TA=125º C
Burn In MIL STD 883 Method 1015 160 Hrs at 90º C, case
Temperature Cycle MIL STD 883, -55ºC to +105ºC, Method 1010 Cond. B

The PICO FC and MC Series of high power DC-DC Converters, allow a wide input voltage of 100-180 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection. 

The availability of Dual Isolated outputs, small size, and the capability of parallel operation as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements. 

This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements. 


Series FC/MC Single * 100 Watts * Input 100-180 VDC

Input
Volt.
Range
(V DC)
Outp.
Volt.
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full
Load
Typical
**
(%)
Max.
Load
Regulation
(%)**
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full
Load)
1-1MHz
BW
(MV P-P)
Outp.
Volt.
Toler.
**
(± %)
Series FC Single
(-40º C to +85º C)
Series MC Single
(-55º C to +85º C)
10-50%
50-100%
100-150V
150-180V
Pico
Part
Number
Price
Pico
Part
Number
Price
100-180
3.3
50
76
1.00
1.00
0.75
0.75
50
2.0
FC3.3S
222.56
MC3.3S
333.84
100-180
5
75
78
1.00
1.00
0.75
0.75
50
1.5
FC5S
222.56
MC5S
333.84
100-180
5.2
75
78
1.00
1.00
0.75
0.75
50
1.5
FC5.2S
222.56
MC5.2S
333.84
100-180
9
100
84
0.75
0.75
0.50
0.50
50
1.0
FC9S
222.56
MC9S
333.84
100-180
12
100
86
0.75
0.75
0.50
0.50
50
1.0
FC12S
222.56
MC12S
333.84
100-180
15
100
87
0.75
0.75
0.50
0.50
50
1.0
FC15S
222.56
MC15S
333.84
100-180
24
100
88
0.50
0.50
0.30
0.30
50
0.5
FC24S
222.56
MC24S
333.84
100-180
28
100
88
0.50
0.50
0.20
0.20
50
0.5
FC28S
222.56
MC28S
333.84
100-180
48
100
88
0.50
0.50
0.20
0.20
50
0.5
FC48S
222.56
MC48S
333.84
100-180
100
100
87
0.50
0.50
0.30
0.30
50
0.5
FC100S
333.84
MC100S
500.76
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)
** Reading taken at nominal 150 VDC input


Series FC/MC Dual * 100 Watts * Input 100-180 VDC

Input
Volt.
Range
(V DC)
Outp.
Volt.
(V DC)
Max.
Output
Power
*
(W)
EFF.
Full
Load
Typical
**
(%)
Max.
Load
Regulation
(%)**
Max.
Line
Regulation
At Full Load
(%)
Output
Voltage
Ripple
(Full
Load)
1-1MHz
BW
(MV P-P)
Outp.
Volt.
Toler.
**
(± %)
Series FC Dual
(-40º C to +85º C)
Series MC Dual
(-55º C to +85º C)
10-50%
50-100%
100-150V
150-180V
Pico
Part
Number
Price
Pico
Part
Number
Price
100-180
5
37.5/37.5
78
1.00
1.00
0.75
0.75
50
1.5
FC5D
318.86
MC5D
478.29
100-180
9
50/50
84
0.75
0.75
0.50
0.50
50
1.0
FC9D
318.86
MC9D
478.29
100-180
12
50/50
86
0.75
0.75
0.50
0.50
50
1.0
FC12D
318.86
MC12D
478.29
100-180
15
50/50
87
0.75
0.75
0.50
0.50
50
1.0
FC15D
318.86
MC15D
478.29
100-180
24
50/50
88
0.50
0.50
0.30
0.30
50
0.5
FC24D
318.86
MC24D
478.29
100-180
28
50/50
88
0.50
0.50
0.20
0.20
50
0.5
FC28D
318.86
MC28D
478.29
100-180
48
50/50
88
0.50
0.50
0.20
0.20
50
0.5
FC48D
318.86
MC48D
478.29
10% Minimum load required at all times.
* Using proper thermal management, maximum temp. of +85º C (case)
** Reading taken at nominal 150 VDC input

****HIGH VOLTAGE SERIES FC/MC
TO 300 VDC   -   100 WATTS   -   INPUT 100-180 VDC

INPUT
VOLTAGE
RANGE
(VDC)
OUTPUT
VOLTAGE
(V DC)
MAX.
OUTPUT
POWER
(W)*
EFF. @
FULL
LOAD
TYP.
(%)**
MAX. LOAD
REGULATION
(%)**
MAX. LINE
REGULATION
AT FULL LOAD
(%)
OUTPUT
VOLTAGE
RIPPLE
FULL LOAD
1-1MHz
BW
(%)
OUTPUT
VOLTAGE
Tolerance
(±%)**
SERIES FC SINGLE
(-40ºC to +85ºC)
SERIES MC SINGLE
(-55ºC to +85ºC)
10-50%
50-100%
100-150V
150-180V
PICO
PART
NUMBER
PRICE
PICO
PART
NUMBER
PRICE
100-180
125
100
85
0.5
0.5
0.3
0.3
1
0.5
FC125S
333.84
MC125S
500.76
100-180
150
100
85
0.5
0.5
0.3
0.3
1
0.5
FC150S
333.84
MC150S
500.76
100-180
175
100
85
0.5
0.5
0.3
0.3
1
0.5
FC175S
333.84
MC175S
500.76
100-180
200
100
85
0.5
0.5
0.3
0.3
1
0.5
FC200S
445.12
MC200S
667.68
100-180
225
100
85
0.5
0.5
0.3
0.3
1
0.5
FC225S
445.12
MC225S
667.68
100-180
250
100
85
0.5
0.5
0.3
0.3
1
0.5
FC250S
445.12
MC250S
667.68
100-180
275
100
85
0.5
0.5
0.3
0.3
1
0.5
FC275S
445.12
MC275S
667.68
100-180
300
100
85
0.5
0.5
0.3
0.3
1
0.5
FC300S
556.40
MC300S
834.60
10% Minimum load required at all times
*Using proper thermal management maximum temp of +85ºC (case)
**Reading taken at nominal 150 VDC input
****UL approval recognition pending

GO TO APPLICATION NOTES
GO TO MECHANICAL CONFIGURATIONS


Larger Version of Graph



For immediate engineering assistance or to place an order: Call Toll Free: 800-431-1064