Features:
Typical Characteristics: Frequency: 100 Khtz
100 VDC Output Models Hi Density 100 Watts Fixed Frequency For all variations, call factory. For Parallel Operation: Add suffix "P" (i.e. HPC5SP) |
The new PICO HPC Series of high power DC-DC Converters, allow a wide input voltage of 100-180 VDC, while maintaining a regulated output. They are fully safeguarded for over voltage, over temperature and continuous short circuit protection. The availability of Dual Isolated Outputs, small size, and the capability of parallel operations as standard features should reduce your design and component costs, while the fixed frequency operation helps parallel connections for higher power requirements. This high density unit is assembled in the USA with PICO quality and component selection, allowing it to meet the most stringent commercial requirements.
|
|
|||||||||||
| Pico Part No. |
Input Voltage Range (V DC) |
Output Voltage (V DC) |
Max. Output Power * (W) |
EFF. Full Load Typical ** (%) |
Max. Load Regulation (%) *** |
Max. Line Regulation At Full Load (%) |
Output Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output Voltage Tolerance ** (± %) |
Price (US $) |
||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10-50% | 50-100% | 100-150 | 150-180 | ||||||||
|
HPC3.3S
|
100-180
|
3.3
|
75
|
71
|
1.50
|
1.50
|
1.25
|
1.25
|
50
|
1.5
|
223.54
|
|
HPC5S
|
100-180
|
5
|
100
|
76
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
223.54
|
|
HPC5.2S
|
100-180
|
5.2
|
100
|
76
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
223.54
|
|
HPC9S
|
100-180
|
9
|
150
|
80
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.0
|
223.54
|
|
HPC12S
|
100-180
|
12
|
200
|
83
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
223.54
|
|
HPC15S
|
100-180
|
15
|
200
|
84
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
223.54
|
|
HPC24S
|
100-180
|
24
|
200
|
86
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.75
|
223.54
|
|
HPC28S
|
100-180
|
28
|
200
|
86
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.75
|
223.54
|
|
HPC48S
|
100-180
|
48
|
200
|
86
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
223.54
|
|
HPC100S
|
100-180
|
100
|
150
|
85
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
286.59
|
| 10%
Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 150 VDC input |
|||||||||||
|
|||||||||||
| Pico Part No. |
Input Voltage Range (V DC) |
Output Voltage (V DC) |
Max. Output Power * (W) |
EFF. Full Load Typical ** (%) |
Max. Load Regulation (%) *** |
Max. Line Regulation At Full Load (%) |
Output Voltage Ripple (Full Load) 1-1MHz BW (MV P-P) |
Output Voltage Tolerance ** (± %) |
Price (US $) |
||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 10-50% | 50-100% | 100-150 | 150-180 | ||||||||
|
HPC5D
|
100-180
|
5
|
50/50
|
76
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.5
|
298.56
|
|
HPC9D
|
100-180
|
9
|
75/75
|
80
|
1.25
|
1.25
|
1.00
|
1.00
|
50
|
1.0
|
298.56
|
|
HPC12D
|
100-180
|
12
|
75/75
|
83
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
298.56
|
|
HPC15D
|
100-180
|
15
|
75/75
|
84
|
1.00
|
1.00
|
0.75
|
0.75
|
50
|
1.0
|
298.56
|
|
HPC24D
|
100-180
|
24
|
75/75
|
86
|
0.75
|
0.75
|
0.75
|
0.75
|
50
|
0.75
|
298.56
|
|
HPC28D
|
100-180
|
28
|
75/75
|
86
|
0.75
|
0.75
|
0.50
|
0.50
|
50
|
0.75
|
298.56
|
|
HPC48D
|
100-180
|
48
|
75/75
|
85
|
0.50
|
0.50
|
0.50
|
0.50
|
50
|
0.50
|
298.56
|
| 10%
Minimum load required at all times. * Using proper thermal management, maximum temp. of +85º C (case) ** Reading taken at nominal 150 VDC input |
|||||||||||
HIGH VOLTAGE SERIES PCTO 300 VDC - 150 WATTS - INPUT 100 - 180 VDC |
|||||||||||
|
PICO
PART NUMBER |
INPUT
VOLTAGE RANGE (VDC) |
OUTPUT
VOLTAGE (DC) |
MAX.
OUTPUT POWER (W)* |
EFF. @
FULL LOAD TYPICAL (%)** |
MAX. LOAD
REGULATION (%)** |
MAX.
LINE
REGULATION AT FULL LOAD (%) |
OUTPUT
VOLTAGE RIPPLE FULL LOAD 1-1MHzBW (%) |
OUTPUT
VOLTAGE TOLERANCE (±%)* |
PRICE
(US $) |
||
|
20 - 50%
|
50 - 100%
|
100 - 150 V
|
150 - 180 V
|
||||||||
|
PC125S
|
100 - 180
|
125
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
|
PC150S
|
100 - 180
|
150
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
|
PC175S
|
100 - 180
|
175
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
214.99
|
|
PC200S
|
100 - 180
|
200
|
150
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
|
PC225S
|
100 - 180
|
225
|
125
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
|
PC250S
|
100 - 180
|
250
|
125
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
|
PC275S
|
100 - 180
|
275
|
100
|
85
|
0.5
|
0.5
|
0.3
|
0.3
|
1
|
0.5
|
286.66
|
PC300S |
100 - 180 |
300 |
100 |
85 |
0.5 |
0.5 |
0.3 |
0.3 |
1 |
0.5 |
358.32 |
| 10% Minimum load required at all times *Using proper thermal management maximum temp. of +85°C (case) **Reading taken at nominal 150 VDC input ****UL approval pending |
|||||||||||